Highlogo LC/LCX/LCSX | Jung Pumpen
Control units and components

Highlogo LC/LCX/LCSX

USER-FRIENDLY MICROPROCESSOR CONTROL UNITS FOR EXPLOSION-PROOF SEWAGE PUMPS WITH A CONNECTED LOAD UP TO 4 KW POWER RATING.

Equipped as standard with digital pressure sensors, these devices control and monitor pump operation, e.g. in pressure drainage and alert in the event of high water or malfunction.

  • Large backlit clear text display
  • Intuitive operation
  • Start-up assistant
  • Multilingual
  • Compact housing
  • ATEX-compliant with electromechanical motor protection
  • With integrated presssure switch

HighLogo microprocessor control units are the convenient solution for monitoring and level-dependent switching of one or two directly starting sewage pumps with or without explosion protection. The compact housings (IP44) of the single and duplex units allow space-saving installation inside the building or in an outdoor column outside.
The operating status of the pump station is indicated via the graphic display and an additional LED. The control system can be operated and set intuitively via multifunction button and push-button. The multilingual menu displays the operating hours and switch-on cycles of the pump(s), the current consumption, any fault messages and a maintenance reminder. An integrated event memory offers additional diagnostic options. Fault messages and a high-water alarm are reported via the display and an alarm buzzer and can be forwarded via potential-free contacts. In addition, direct connection of a 230V warning signal is possible.
A high-water alarm can also be signalled in the event of a mains failure by means of an optional 9V battery. In addition, it is possible to issue differentiated fault messages via SMS and e-mail using an optionally integrated GSM modem.
Especially for pressure drainage or for sewage pumps in pump sumps up to Ø 1.5 m, the HighLogo control units (LC variant) are already equipped with a dynamic pressure level system as standard. The two integrated pressure switches are connected via air hoses to the open dynamic pressure bells hanging in the pump shaft. This 2-circuit system provides additional safety in the event of a high water level. The submersible switch dry run protection (DRP), which is also included in the scope of delivery, together with the mechanical motor protection and the runtime monitoring during pump operation, fulfils the requirements of the ATEX directive for explosion protection. (ATEX mode selectable via menu navigation)

18 results

TypeCode No.Motor protectionPre-fuseAutomatic alternate operationMotor protection typPeak load operationTypeMain switch
JP47984
2.4 ... 4 A
16 A
No
Overload rely
No
Single units with pressure switches and tube set (10 m ) and DRP
No
JP47985
4 ... 6 A
16 A
No
Overload rely
No
Single units with pressure switches and tube set (10 m ) and DRP
No
JP47986
6 ... 9 A
16 A
No
Overload rely
No
Single units with pressure switches and tube set (10 m ) and DRP
No
JP48286
2.4 ... 4 A
16 A
No
Overload rely
No
Single units with pressure switches, without tube set and DRP
No
JP48287
4 ... 6 A
16 A
No
Overload rely
No
Single units with pressure switches, without tube set and DRP
No
JP48288
6 ... 9 A
16 A
No
Overload rely
No
Single units with pressure switches, without tube set and DRP
No
JP48292
2.4 ... 4 A
16 A
No
Overload rely
No
Single units with pressure switches, without tube set and DRP, with main switch
Yes
JP48293
4 ... 6 A
16 A
No
Overload rely
No
Single units with pressure switches, without tube set and DRP, with main switch
Yes
JP48294
6 ... 9 A
16 A
No
Overload rely
No
Single units with pressure switches, without tube set and DRP, with main switch
Yes
JP47993
2.5 ... 4 A
16 A
Yes
Motor protection switch
Yes
Duplex unit with pressure switches and tube sets (10 m) and DRP
No
JP47994
4 ... 6.3 A
20 A
Yes
Motor protection switch
Yes
Duplex unit with pressure switches and tube sets (10 m) and DRP
No
JP47995
6.3 ... 10 A
25 A
Yes
Motor protection switch
Yes
Duplex unit with pressure switches and tube sets (10 m) and DRP
No
JP48289
2.5 ... 4 A
16 A
Yes
Motor protection switch
Yes
Duplex units with pressure switches, without tube set and DRP
No
JP48290
4 ... 6.3 A
20 A
Yes
Motor protection switch
Yes
Duplex units with pressure switches, without tube set and DRP
No
JP48291
6.3 ... 10 A
25 A
Yes
Motor protection switch
Yes
Duplex units with pressure switches, without tube set and DRP
No
JP48295
2.5 ... 4 A
16 A
Yes
Motor protection switch
Yes
Duplex units with pressure switches, without tube set and DRP, with main switch
Yes
JP48296
4 ... 6.3 A
20 A
Yes
Motor protection switch
Yes
Duplex units with pressure switches, without tube set and DRP, with main switch
Yes
JP48297
6.3 ... 10 A
25 A
Yes
Motor protection switch
Yes
Duplex units with pressure switches, without tube set and DRP, with main switch
Yes

Mindig jól informált!

Iratkozzon fel hírlevelünkre


Közvetlen kapcsolat

Jung Pumpen GmbH

hu.jp@pentair.com

Ferenc Besenyei Farkas

Fon: +36 30 346 5605
Magyarországi Közvetlen Kereskedelmi Képviselet, Andrássy út 121
1133 Budapest, Hungary

JUNG PUMPEN GmbH

Industriestraße 4-6
33803 Steinhagen
Germany
Fon +49 5204 17-0
E-Mail info@jung-pumpen.de