HIGHLOGO 2-610 LCX | Jung Pumpen

HIGHLOGO 2-610 LCX

JP48291
Mechanical data
Type
Duplex units with pressure switches, without tube set and DRP
HxWxL[mm]
275 x 250 x 155
Weight
4 kg
Main switch
No
Electrical data
Pump voltage
3/N/PE~400 V
Motor protection
6.3 ... 10 A
Pre-fuse
25 A
Type of enclosure
IP 44
Alarm buzzer
Yes
Connection 9V battery
Yes
Connection thermal contact
Yes
Connection dry run protection
Yes
Display operation hours/switching cycles
Yes
Display amps
Yes
Automatic alternate operation
Yes
Automatic test run
Yes
Digital signal contact
optinoal
Input AUX
Yes
Input level control
digital and analog
Switch off delay after power outage
Yes
Event memory
Yes
Integrated GSM-Modem
optinoal
Run time monitoring
Yes
Max. switching power
4 kW 3x400V
Motor protection typ
Motor protection switch
Stop time for pump operation
Yes
Peak load operation
Yes
Start
direct
Fault contact pot. Free
2 changeover contacts, 5A
Equipment HighLogo LC
Equipment HighLogo LCX/LCSX
Electrical accessory
Code No.
a
Tube set
15 m, DRP pressure switch and tube set JP48302
b
Level control
Weight to stabilize the subm. ball contact switch JP44803
c
Rechargeable battery
9 V, for mains independent alarm JP44850
d
Pre-mounted accessory
Parametrization GSM modul pre-setting for customer demand JP55202
GSM battery fpr HighLogo 1 12V, for single unit, factory fitted JP25884
GSM battery fpr HighLogo 2 12V, for duplex units, factory fitted incl. housing extension JP49357
e
Retrofittable accessory
CEE-Plug 32 A 1.5 m cable JP50817
Modem GSM for HighLogo retrofit unit incl. GSM antenna JP50444
Battery 12V with housing retrofit unit for independent modem operation JP50635

Mindig jól informált!

Iratkozzon fel hírlevelünkre


Közvetlen kapcsolat

Jung Pumpen GmbH

hu.jp@pentair.com

Ferenc Besenyei Farkas

Fon: +36 30 346 5605
Magyarországi Közvetlen Kereskedelmi Képviselet, Andrássy út 121
1133 Budapest, Hungary

JUNG PUMPEN GmbH

Industriestraße 4-6
33803 Steinhagen
Germany
Fon +49 5204 17-0
E-Mail info@jung-pumpen.de