Sewage pumps
MultiCut Tandem
- Reliable solids transport due to improved cutting technology
- High delivery head
- External adjustable cutting mechanism
- Controllable oil chamber
- SiC mechanical seal independent of sense of rotation
- Moisture-sealed cable inlet with plug-in cable connection
- Installed motor protection
Centrifugal submersible sewage pumps fitted with the MultiCut cutting system are used as stationary appliances in pressurised drainage systems for discharge in sparsely populated areas or of detached houses. They are suitable for pumping domestic wastewater with the usual additions (as specified in German standard DIN 1986, Part 3). In the MultiCut tandem systems (TAN), two MultiCut pumps are connected to one unit in order to achieve a higher head.
For pumping from ducts which are connected to the public sewer system, explosion-proof submersible pumps of the UFK series have to be used. On account of the upstream cutting system, the pressurised line as from DN 32 - as from DN 80 minimum without cutting system - may be routed parallel to the terrain.
Operating conditions up to a temperature of the material to be transported of 40° Celsius
Submerged motor:
Continuous operation (S1)
Emerged motor:
Intermittent operation (S3) (e.g. 40% = 4 min. operation, 6 min. break)
The unique MultiCut cutting system ensures a maximum of operational safety at outstanding delivery characteristics. Fitted with a cutter plate made of hardened stainless steel and a three-bladed knife, it disintegrates coarse additions in the wastewater with more than 200,000 cutting processes per minute before they can get into the pump hydraulics. Solids which cannot be transported are rejected outside of the pump by the cutting rotor as the cutting system is located upstream from the pump hydraulics. Specifically arranged grooves on the cutter plate ensure additional safety as the cutting unit is permanently cleaned automatically during the delivery.
Sewage pumps with ex-proof in keeping with German/European standard EN 12050, 10 m cable, without plug.
Ex II 2 G Ex db IIB T4 Gb
Attention: Further mechanical and eletrical accessory on request. All electrical data refer to a single pump!
Delivery head Hmax | 86 m |
Flow rate Qmax | 16 m³/h |
Specifications can be changed without notice. Performance subject to ISO 9906 tolerances.
The minimum flow velocity in the pressure piping must be 0.7 m/s according to EN 12056.
This data is represented in the performance curve as a limit of application.
3 results
Type | Code No. | Motor rating P1 | Motor rating P2 | Current | S3 |
---|---|---|---|---|---|
JP50362 | 3.7 kW | 3.04 kW | 6.6 A | 40 % | |
JP50368 | 4.2 kW | 3.42 kW | 7.3 A | 30 % | |
JP50374 | 4.84 kW | 3.93 kW | 7.9 A | 25 % |