U3KS, 4 m cable
JP50000Mechanical data | |
---|---|
Pump | Vertical single-stage |
Free passage | 10 mm |
Bearing | Ball bearings, grease-lubricated |
Seal on motor side | Rotary shaft seal |
Oil chamber | Yes |
Seal on medium side | 2-fold rotary shaft seals |
Run dry protection | Yes |
Shaft | Stainless steel |
Impeller | Vortex impeller, GFK |
Motor housing | Stainless steel |
Pump housing | GRP |
Submersible | Yes |
Pressure outlet | 1 1/4" |
Weight | 3.4 kg |
Electrical data | |
---|---|
Ciruit | With built-in level control |
Voltage | 1/N/PE~230 V |
Motor rating P1 | 0.32 kW |
Motor rating P2 | 0.2 kW |
Current | 1.4 A |
Power line | 4m H05RN-F |
Wires | 3G0,75 |
Type of enclosure | IP 68 |
Insulation class | F |
Winding thermostat | Yes |
Motor protection | Integrated |
Plug | Safety |

Performance | ||||||
---|---|---|---|---|---|---|
Delivery head H [m] | 1 | 2 | 3 | 4 | 5 | 6 |
Flow rate Q [m³/h] | 6.5 | 6 | 5.7 | 5 | 4 | 2.4 |
Specifications can be changed without notice. Performance subject to ISO 9906 tolerances.
The minimum flow velocity in the pressure piping must be 0.7 m/s according to EN 12056.
This data is represented in the performance curve as a limit of application.








Single unit with GR: sump area min. 40x50 cm or Ø 50 cm
Single unit without GR: sump area min. 40x40 cm or Ø 40 cm
Duplex unit with GR: sump area min. 50x50 cm, Ø 60 cm
Duplex unit without GR: sump area min. 50x50, Ø 55 cm
Single unit Easyfix 32 Single: sump min. 30x40 cm, Ø 40 cm
Duplex unit Easyfix 32 Duo: sump min. 45x40 cm, Ø 55 cm
Duplex unit Easyfix 32 Duo with special float: sump min. 50x50 cm Ø 70 cm
In case of installation beneath the backpressure level the pressure tube must be taken in a loop over the local backup level acc. to EN 12056. Besides, it must be secured with an EN 12050-4-proofed swing-type check valve. Additionally we recommend an alarm system.
In accordance with EN 12056-4 section 5.1, it has a built-in automatic spare pump or a double attachment included, which ensures that sewage drainage is not interrupted.
Suspend control unit in a dry room
Mechanical accessory | ||||||
---|---|---|---|---|---|---|
Code No. | ||||||
Swing-type check valve | ||||||
R32 EN 12050-4 | 1¼“ (DN 32), PN 4 | 90x90 (HxB) | JP09739 | |||
Rupper flap DN32 | for transportable use | 35x35 (HxB) | JP50774 | |||
Stop valve | ||||||
1¼“ (DN 32), PN 16 | 110x60 (HxB) | JP44785 | ||||
Elastic connection | ||||||
+ Hose band clamps, 1¼“ (DN 32), PN 3 | 100x42 (HxD) | JP50901 | ||||
Hose coupling | ||||||
Hose coupling | 1¼“ (DN 25) brass, for transportable use | JP50849 | ||||
Pressure hose | ||||||
15 m, synthetic, Ø 25 mm | JP50830 | |||||
House connection | 1¼“ – 38/32/25 | JP44209 | ||||
Hose set | ||||||
1 1/4" (DN32), 15 m PVC hose c/w elbow | JP43550 | |||||
Special float | ||||||
for lower switching points | JP44795 | |||||
for narrow chambers (mind. 30x30 od Ø30 cm) | JP40856 | |||||
Float fixation | for continuous pump operation | JP42175 | ||||
Guide rail system | ||||||
GR 32 | JP44000 | |||||
Support for guide rail extension | ex 2 m sump depth, per m 1 piece | JP28314 | ||||
Easyfix 32 Single | ready-to-connect installation set | JP50308 | ||||
Easyfix 32 Duo | ready-to-connect installation set with control unit for duplex units | JP50307 | ||||
Connection kit | ||||||
DN 32, with telescopable pressure pipe 30-90 cm | JP44609 |
Electrical accessory | ||||||
---|---|---|---|---|---|---|
Code No. | ||||||
Alarm unit | ||||||
AG3 | subm. ball contact switch, mains dependent, potential-free contact,3 m cable | JP44891 | ||||
AG10 | subm. ball contact switch, mains dependent, potential-free contact, 9.5 m cable | JP44892 | ||||
Washing machine stop | ||||||
AW3 | subm. ball contact switch, mains dependent, 3 m cable | JP44895 | ||||
Rechargeable battery | ||||||
9 V, for mains independent alarm | JP44850 |