U6K ES, 10 m cable
JP09260| Mechanical data | |
|---|---|
| Pump | Vertical single-stage |
| Free passage | 20 mm |
| Bearing | Ball bearings, grease-lubricated |
| Seal on motor side | Rotary shaft seal |
| Oil chamber | Yes |
| Seal on medium side | SiC mechanical seal |
| Run dry protection | Yes |
| Shaft | Stainless steel |
| Impeller | Vortex impeller, GFK |
| Motor housing | Stainless steel |
| Submersible | Yes |
| Pressure outlet | 1 1/4" |
| Weight | 6.2 kg |
| Electrical data | |
|---|---|
| Ciruit | With built-in level control |
| Voltage | 1/N/PE~230 V |
| Motor rating P1 | 0.75 kW |
| Motor rating P2 | 0.5 kW |
| Current | 3.3 A |
| Power line | 10m H07RN-F |
| Wires | 3G1,0 |
| Type of enclosure | IP 68 |
| Insulation class | B |
| Winding thermostat | Yes |
| Motor protection | Integrated |
| Plug | Safety |
| Performance | |||||||||
|---|---|---|---|---|---|---|---|---|---|
| Delivery head H [m] | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 |
| Flow rate Q [m³/h] | 15.5 | 14.5 | 13 | 11.5 | 9.5 | 8 | 6 | 4 | 1.5 |
Specifications can be changed without notice. Performance subject to ISO 9906 tolerances.
The minimum flow velocity in the pressure piping must be 0.7 m/s according to EN 12056.
This data is represented in the performance curve as a limit of application.
Single unit with GR: sump area min. 40x50 cm or Ø 50 cm
Single unit without GR: sump area min. 40x40 cm or Ø 40 cm
Duplex unit with GR: sump area min. 50x55 cm, Ø 65 cm
Duplex unit without GR: sump area min. 50x50, Ø 55 cm
Single unit Easyfix 32 Single: sump min. 30x45 cm, Ø 45 cm
Duplex unit Easyfix 32 Duo: sump min. 50x40 cm, Ø 60 cm
Duplex unit Easyfix 32 Duo with special float: sump min. 50x50 cm Ø 70 cm
In case of installation beneath the backpressure level the pressure tube must be taken in a loop over the local backup level acc. to EN 12056. Besides, it must be secured with an EN 12050-4-proofed swing-type check valve. Additionally we recommend an alarm system.
In accordance with EN 12056-4 section 5.1, it has a built-in automatic spare pump or a double attachment included, which ensures that sewage drainage is not interrupted.
Suspend control unit in a dry room
| Mechanical accessory | ||||||
|---|---|---|---|---|---|---|
| Code No. | ||||||
| Swing-type check valve | ||||||
| R32 EN 12050-4 | 1¼“ (DN 32), PN 4 | 90x90 (HxB) | JP09739 | |||
| Rubber flap DN32 | for transportable use | 35x35 (HxB) | JP50774 | |||
| Stop valve | ||||||
| 1¼“ (DN 32), PN 16 | 110x60 (HxB) | JP44785 | ||||
| Elastic connection | ||||||
| + Hose band clamps, 1¼“ (DN 32), PN 3 | 100x42 (HxD) | JP50901 | ||||
| Hose coupling | ||||||
| Coupling Storz C | 1 1/4" male thread | JP44780 | ||||
| Coupling wrench | JP25708 | |||||
| Pressure hose | ||||||
| 12,5 m, synthetic, with coupling Storz C, Ø 38 mm | JP50298 | |||||
| Hose set | ||||||
| 1 1/4" (DN32), 15 m PVC hose c/w elbow | JP43550 | |||||
| Special float | ||||||
| for lower switching points (U5 and U6) | JP44207 | |||||
| for narrow chambers (mind. 30x30 od Ø30 cm) | JP40856 | |||||
| Float fixation | for continuous pump operation | JP42175 | ||||
| Guide rail system | ||||||
| GR 32 | JP44000 | |||||
| Support for guide rail extension | ex 2 m sump depth, per m 1 piece | JP28314 | ||||
| Easyfix 32 Single | ready-to-connect installation set | JP50308 | ||||
| Easyfix 32 Duo | ready-to-connect installation set with control unit for duplex units | JP50307 | ||||
| Connection kit | ||||||
| DN 32, with telescopable pressure pipe 30-90 cm | JP44609 | |||||
| Electrical accessory | ||||||
|---|---|---|---|---|---|---|
| Code No. | ||||||
| Alarm unit | ||||||
| AG3 | subm. ball contact switch, mains dependent, potential-free contact,3 m cable | JP44891 | ||||
| AG10 | subm. ball contact switch, mains dependent, potential-free contact, 9.5 m cable | JP44892 | ||||
| Washing machine stop | ||||||
| AW3 | subm. ball contact switch, mains dependent, 3 m cable | JP44895 | ||||
| Rechargeable battery | ||||||
| 9 V, for mains independent alarm | JP44850 | |||||