Highlogo LC | Jung Pumpen
Coffrets de commande et composants

Highlogo LC

USER-FRIENDLY MICROPROCESSOR CONTROL UNITS FOR EXPLOSION-PROOF SEWAGE PUMPS WITH A CONNECTED LOAD UP TO 4 KW POWER RATING.

Equipped as standard with digital pressure sensors, these devices control and monitor pump operation, e.g. in pressure drainage and alert in the event of high water or malfunction.

  • Grand écran éclairé avec affichage en texte clair
  • Utilisation intuitive
  • Menu de première mise en service
  • Multilingue
  • Forme de construction compacte
  • Conforme à la norme ATEX avec protection électromécanique du moteur
  • With integrated presssure switch

Les commandes à microprocesseur HighLogo sont la solution confortable pour la surveillance et la commutation en fonction du niveau d'une ou deux pompes d'eaux usées à démarrage direct avec ou sans protection antidéflagrante. Les boîtiers compacts (IP44) des installations simples et doubles permettent une installation peu encombrante à l'intérieur du bâtiment ou dans une colonne en plein air à l'extérieur.
L'état de fonctionnement de la station de pompage est indiqué par l'écran graphique et une LED supplémentaire. Un bouton multifonctionnel et un bouton-poussoir permettent d'utiliser et de régler la commande de manière intuitive. Le menu multilingue permet d'afficher les heures de fonctionnement et les cycles de mise en marche de la ou des pompes, la consommation électrique, les éventuels messages d'erreur et un rappel d'entretien. Une mémoire d'événements intégrée offre des possibilités de diagnostic supplémentaires. Les messages d'erreur et une alarme de crue sont signalés par l'écran et un buzzer d'alarme et peuvent être transmis par des contacts sans potentiel. Il est en outre possible de raccorder directement un détecteur d'alerte de 230V.
Même en cas de panne de secteur, une alarme de crue peut être signalée au moyen d'une batterie 9V en option.De plus, il est possible d'envoyer des messages d'erreur différenciés par SMS via un modem GSM intégré en option.
Les commandes HighLogo (variante LC) sont déjà équipées en série d'un système de niveau de pression dynamique, spécialement conçu pour l'évacuation sous pression ou pour les pompes à eaux usées dans les puits de pompage jusqu'à Ø 1,5 m.Les deux pressostats intégrés sont reliés par des tuyaux d'air aux cloches de pression dynamique ouvertes suspendues dans le puits de la pompe.Ce système à deux circuits offre une sécurité supplémentaire en cas de niveau d'eau élevé.Le commutateur immergé Protection contre la marche à sec (TLS), également compris dans la livraison, répond, avec la protection mécanique du moteur et le contrôle de la durée de fonctionnement en mode pompe, aux exigences de la directive ATEX sur la protection contre les explosions.(Mode ATEX sélectionnable via le menu)

24 Résultats

TypeArt.-Nr.Protection du moteurFusibleAutomatic alternate operationType protection moteurOpération de charge de pointeTypeInterrupteur général
JP47984
2,4 ... 4 A
16 A
Non
Overload rely
Non
Single units with pressure switches and tube set (10 m ) and DRP
Non
JP47985
4 ... 6 A
16 A
Non
Overload rely
Non
Single units with pressure switches and tube set (10 m ) and DRP
Non
JP47986
6 ... 9 A
16 A
Non
Overload rely
Non
Single units with pressure switches and tube set (10 m ) and DRP
Non
JP50820
2,4 ... 4 A
16 A
Non
Overload rely
Non
Single units with pressure switches, tube set and DRP, with main switch
Oui
JP50821
4 ... 6 A
16 A
Non
Overload rely
Non
Single units with pressure switches, tube set and DRP, with main switch
Oui
JP50822
6 ... 9 A
16 A
Non
Overload rely
Non
Single units with pressure switches, tube set and DRP, with main switch
Oui
JP48286
2,4 ... 4 A
16 A
Non
Overload rely
Non
Single units with pressure switches, without tube set and DRP
Non
JP48287
4 ... 6 A
16 A
Non
Overload rely
Non
Single units with pressure switches, without tube set and DRP
Non
JP48288
6 ... 9 A
16 A
Non
Overload rely
Non
Single units with pressure switches, without tube set and DRP
Non
JP48292
2,4 ... 4 A
16 A
Non
Overload rely
Non
Single units with pressure switches, without tube set and DRP, with main switch
Oui
JP48293
4 ... 6 A
16 A
Non
Overload rely
Non
Single units with pressure switches, without tube set and DRP, with main switch
Oui
JP48294
6 ... 9 A
16 A
Non
Overload rely
Non
Single units with pressure switches, without tube set and DRP, with main switch
Oui
JP47993
2,5 ... 4 A
16 A
Oui
Motor protection switch
Oui
Duplex unit with pressure switches and tube sets (10 m) and DRP
Non
JP47994
4 ... 6,3 A
20 A
Oui
Motor protection switch
Oui
Duplex unit with pressure switches and tube sets (10 m) and DRP
Non
JP47995
6,3 ... 10 A
25 A
Oui
Motor protection switch
Oui
Duplex unit with pressure switches and tube sets (10 m) and DRP
Non
JP50823
2,5 ... 4 A
16 A
Oui
Motor protection switch
Oui
Duplex units with pressure switches, tube set and DRP, with main switch
Oui
JP50824
4 ... 6,3 A
20 A
Oui
Motor protection switch
Oui
Duplex units with pressure switches, tube set and DRP, with main switch
Oui
JP50825
6,3 ... 10 A
25 A
Oui
Motor protection switch
Oui
Duplex units with pressure switches, tube set and DRP, with main switch
Oui
JP48289
2,5 ... 4 A
16 A
Oui
Motor protection switch
Oui
Duplex units with pressure switches, without tube set and DRP
Non
JP48290
4 ... 6,3 A
20 A
Oui
Motor protection switch
Oui
Duplex units with pressure switches, without tube set and DRP
Non
JP48291
6,3 ... 10 A
25 A
Oui
Motor protection switch
Oui
Duplex units with pressure switches, without tube set and DRP
Non
JP48295
2,5 ... 4 A
16 A
Oui
Motor protection switch
Oui
Duplex units with pressure switches, without tube set and DRP, with main switch
Oui
JP48296
4 ... 6,3 A
20 A
Oui
Motor protection switch
Oui
Duplex units with pressure switches, without tube set and DRP, with main switch
Oui
JP48297
6,3 ... 10 A
25 A
Oui
Motor protection switch
Oui
Duplex units with pressure switches, without tube set and DRP, with main switch
Oui