US 73 E Ex
JP09292| Mechanical data | |
|---|---|
| Pump | Vertical single-stage |
| Ex-proof | With ex-proof |
| Free passage | 30 mm |
| Bearing | Ball bearings, grease-lubricated |
| Seal on motor side | Duplex rotary shaft seals |
| Oil chamber | Yes |
| Seal on medium side | SiC mechanical seal |
| Run dry protection | Yes |
| Shaft | Stainless steel |
| Impeller | Vortex impeller, GFK |
| Motor housing | Grey cast iron |
| Submersible | Yes |
| Pressure outlet | IG 1 1/2" |
| Weight | 19 kg |
| Electrical data | |
|---|---|
| Voltage | 1/N/PE~230 V |
| Motor rating P1 | 0.83 kW |
| Motor rating P2 | 0.5 kW |
| Current | 3.9 A |
| Power line | 10m H07RN-F |
| Wires | 6G1,5 |
| Type of enclosure | IP 68 |
| Insulation class | F |
| Winding thermostat | Yes |
| Plug | Without |
| Performance | |||||||||
|---|---|---|---|---|---|---|---|---|---|
| Delivery head H [m] | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 |
| Flow rate Q [m³/h] | 19 | 17 | 15 | 12 | 10 | 8 | 6 | 4 | 2 |
Specifications can be changed without notice. Performance subject to ISO 9906 tolerances.
The minimum flow velocity in the pressure piping must be 0.7 m/s according to EN 12056.
This data is represented in the performance curve as a limit of application.
Single unit 1½" with GR 40: sump area min. 40x60 cm
Single unit 1½" without GR: sump area min. 40x40 cm
Duplex unit 1½" with GR 40: sump area min. 60x60 cm
Duplex unit 1½" without GR: sump area min. 40x60 cm
In case of installation beneath the backpressure level the pressure tube must be taken in a loop over the local backup level acc. to EN 12056. Besides, it must be secured with an EN 12050-4-proofed swing-type check valve. Additionally we recommend an alarm system.
In accordance with EN 12056-4 section 5.1, it has a built-in automatic spare pump or a double attachment included, which ensures that sewage drainage is not interrupted.
Suspend control unit in a dry room
| Mechanical accessory | ||||||
|---|---|---|---|---|---|---|
| Code No. | ||||||
| Swing-type check valve | ||||||
| R40 EN 12050-4 | 1½“ (DN 40), PN 4 | 150x120 (HxB) | JP00317 | |||
| DR 40 EN 12050-4 | 1½“ (DN 40), PN 4 | 200x280 (HxB) | JP09155 | |||
| Ball-type check valve | ||||||
| KE40 EN 12050-4 | 1½“ (DN 40), PN 6 | 170x125 (HxB) | JP47974 | |||
| Stop valve | ||||||
| brass, 1½“ (DN 40), PN 16 | 125x60 (HxB) | JP44786 | ||||
| Elastic connection | ||||||
| + Hose band clamps, 1½“ (DN 40), PN 4 | 120x50 (HxD) | JP50902 | ||||
| Elbow | ||||||
| 1½“ | JP45953 | |||||
| Chain | ||||||
| certified, 2.5 m, 320 kg, 5 rings (EN 818 mod.) | JP45901 | |||||
| certified, 5.0 m, 320 kg, 8 rings (EN 818 mod.) | JP45902 | |||||
| Webbing | ||||||
| with shackle | JP45168 | |||||
| Guide rail system | ||||||
| GR 40 | JP25592 | |||||
| Electrical accessory | ||||||
|---|---|---|---|---|---|---|
| Code No. | ||||||
| Level control | ||||||
| Auxiliary switch unit ExH-A | for ex-proof pumps only (single-units) | JP16720 | ||||
| Control for single units | ||||||
| Control unit AD 4 XE | for US 73E EX | JP25901 | ||||
| Level control | ||||||
| Subm. switch pack AmG | 2 subm. ball contact switch with 9.5 m and counterweight | JP16719 | ||||
| Level control | ||||||
| Dry run protection US_Ex | JP44603 | |||||