UV 620-3 | Jung Pumpen

UV 620-3

JP47339
Mechanical data
Pump
Vertical single-stage
Free passage
10 mm
Bearing
Ball bearings, grease-lubricated
Seal on motor side
Mechanical seal
Oil chamber
Yes
Seal on medium side
SiC mechanical seal
Run dry protection
Yes
Submersible
Yes
Pressure outlet
IG 2"
Weight
23 kg
Electrical data
Ciruit
Without level control
Voltage
3/PE~400 V
Motor rating P1
2.38 kW
Motor rating P2
1.95 kW
Current
4.6 A
Power line
10m H07RN8-F
Wires
4G1,0
Type of enclosure
IP 68
Insulation class
F
Winding thermostat
Yes
Motor protection
on request
Plug
Without
Performance
Delivery head H [m] 681012141618
Flow rate Q [m³/h] 3734322824185

Specifications can be changed without notice. Performance subject to ISO 9906 tolerances.

The minimum flow velocity in the pressure piping must be 0.7 m/s according to EN 12056.
This data is represented in the performance curve as a limit of application.

Dimensions UV 600 (mm)
Example of single unit installation with GR
Example of duplex unit installation

Single unit 2" with GR 50: sump area min. 40x70 cm
Single unit 2" without GR: sump area min. 40x50 cm

Duplex unit 2" with GR 50: sump area min. 70x70 cm
Duplex unit 2" without GR: sump area min. 50x70 cm

In case of installation beneath the backpressure level the pressure tube must be taken in a loop over the local backup level acc. to EN 12056. Besides, it must be secured with an EN 12050-4-proofed swing-type check valve. Additionally we recommend an alarm system.

In accordance with EN 12056-4 section 5.1, it has a built-in automatic spare pump or a double attachment included, which ensures that sewage drainage is not interrupted.

Suspend control unit in a dry room

Mechanical accessory
Code No.
1
Swing-type check valve
R50 EN 12050-4 2“ (DN 50), PN 4 150x120 (HxB) JP00326
Ball-type check valve
K50 EN 12050-4 2“ (DN 50), PN 6 185x155 (HxB) JP44782
2
Stop valve
brass, 2“ (DN 50), PN 16 140x70 (HxB) JP44787
3
Elastic connection
2“ (DN 50), PN 4 150x63 (HxD) JP44775
4
Hose band clamp
2" JP44764
5
Hose coupling
Coupling Storz C 2" male thread JP50217
Coupling wrench JP25708
Pressure hose
12,5 m, synthetic, with coupling Storz C, Ø 38 mm JP50298
15 m, synthetic, with coupling Storz C, Ø 52 mm JP00336
6
Chain
certified, 2.5 m, 320 kg, 5 rings (EN 818 mod.) JP45901
certified, 5.0 m, 320 kg, 8 rings (EN 818 mod.) JP45902
certified, 7.5 m, 320 kg, 11 rings (EN 818 mod.) JP47365
Shackle, certified, 630 kg, stainless steel JP45904
7
Guide rail system
GR 50 JP25593
Securing lever UV 600 JP49171
Guide rail 1" 1500 mm JP48937
Guide rail 1" 2000 mm JP48938
Guide rail 1" 2500 mm JP48939
Guide rail 1" 3000 mm JP48940
Electrical accessory
Code No.
a
Alarm unit
AG10 subm. ball contact switch, mains dependent, potential-free contact, 9.5 m cable JP44892
b
Control for single units
Control unit 1-46 JP47990
Control unit AD 46 JP14353
Control for duplex units
Control unit HIGHLOGO 2-46 400 V JP47999
Control unit BD 46 400 V, for pumps US 251-253, UV 620-3, UV 625-3 JP45739
Level control
Subm. switch pack AmG 2 subm. ball contact switch with 9.5 m and counterweight JP16719
Subm. switch pack BmG 3 subm. ball contact switch with 9.5 m and counterweight JP16726
Protective motor plug
CEE motor protection 4.5-6.3 A 400 V with level control JP09726
c
Rechargeable battery
9 V, for mains independent alarm JP44850

Always well informed!

Subscribe to our newsletter


Direct contact

Sales Hotline

Fon + 49 5204 / 17-160

Sales E-Mail

sales.jp@pentair.com

JUNG PUMPEN GmbH

Industriestraße 4-6
33803 Steinhagen
Germany
Fon +49 5204 17-0
E-Mail info@jung-pumpen.de