US 73 HES
JP09264Mechanical data | |
---|---|
Pump | Vertical single-stage |
Free passage | 30 mm |
Bearing | Ball bearings, grease-lubricated |
Seal on motor side | Duplex rotary shaft seals |
Oil chamber | Yes |
Seal on medium side | SiC mechanical seal |
Run dry protection | Yes |
Shaft | Stainless steel |
Impeller | Vortex impeller, GFK |
Motor housing | Stainless steel |
Pump housing | Grey cast iron |
Submersible | Yes |
Pressure outlet | IG 1 1/2" |
Weight | 12.5 kg |
Electrical data | |
---|---|
Ciruit | With built-in level control |
Voltage | 1/N/PE~230 V |
Motor rating P1 | 0.83 kW |
Motor rating P2 | 0.5 kW |
Current | 3.9 A |
Power line | 10m H07RN-F |
Wires | 3G1,0 |
Type of enclosure | IP 68 |
Insulation class | F |
Winding thermostat | Yes |
Motor protection | Integrated |
Plug | Safety |

Performance | |||||||||
---|---|---|---|---|---|---|---|---|---|
Delivery head H [m] | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 |
Flow rate Q [m³/h] | 19 | 17 | 15 | 12 | 10 | 8 | 6 | 4 | 2 |
Specifications can be changed without notice. Performance subject to ISO 9906 tolerances.
The minimum flow velocity in the pressure piping must be 0.7 m/s according to EN 12056.
This data is represented in the performance curve as a limit of application.




Single unit US-H with GR 40: sump area min. 40x65 cm
Single unit US-H without GR: sump area min. 40x40 cm
Duplex unit US-H with GR 40: sump area min. 65x80 cm
Duplex unit US-H without GR: sumpe area min. 40x80 cm
In case of installation beneath the backpressure level the pressure tube must be taken in a loop over the local backup level acc. to EN 12056. Besides, it must be secured with an EN 12050-4-proofed swing-type check valve. Additionally we recommend an alarm system.
In accordance with EN 12056-4 section 5.1, it has a built-in automatic spare pump or a double attachment included, which ensures that sewage drainage is not interrupted.
Suspend control unit in a dry room
Mechanical accessory | ||||||
---|---|---|---|---|---|---|
Code No. | ||||||
Swing-type check valve | ||||||
for hot water | 1½“ (DN 40) | 80x85 (HxB) | JP44784 | |||
Ball-type check valve | ||||||
KE40 EN 12050-4 | 1½“ (DN 40), PN 6 | 170x125 (HxB) | JP47974 | |||
Stop valve | ||||||
brass, 1½“ (DN 40), PN 16 | 125x60 (HxB) | JP44786 | ||||
Elbow | ||||||
1½“ | JP45953 | |||||
Special float | ||||||
for lower switching points | JP44795 | |||||
Chain | ||||||
certified, 2.5 m, 320 kg, 5 rings (EN 818 mod.) | JP45901 | |||||
certified, 5.0 m, 320 kg, 8 rings (EN 818 mod.) | JP45902 | |||||
Webbing | ||||||
with shackle | JP45168 | |||||
Guide rail system | ||||||
GR 40 | JP25592 |
Electrical accessory | ||||||
---|---|---|---|---|---|---|
Code No. | ||||||
Alarm unit | ||||||
AG3 | subm. ball contact switch, mains dependent, potential-free contact,3 m cable | JP44891 | ||||
AG10 | subm. ball contact switch, mains dependent, potential-free contact, 9.5 m cable | JP44892 | ||||
Washing machine stop | ||||||
AW3 | subm. ball contact switch, mains dependent, 3 m cable | JP44895 | ||||
AWO | for alarm forwarding in case of several washing machines | JP44899 | ||||
Rechargeable battery | ||||||
9 V, for mains independent alarm | JP44850 | |||||
Smart Home | ||||||
FTJP radio transmitter | JP47209 |