MultiCut 08/2 MS
JP50345Mechanical data | |
---|---|
Pump | Vertical single-stage |
Bearing | Ball bearings, grease-lubricated |
Seal on motor side | Duplex rotary shaft seals |
Oil chamber | Yes |
Seal on medium side | SiC mechanical seal |
Run dry protection | Yes |
Impeller | Vortex impeller, GFK |
Motor housing | Stainless steel |
Pump housing | Grey cast iron |
Submersible | Yes |
Pressure outlet | DN 32 |
Weight | 17.2 kg |
Electrical data | |
---|---|
Ciruit | With built-in level control |
Voltage | 3/PE~400 V |
Motor rating P1 | 1.65 kW |
Motor rating P2 | 1.24 kW |
Current | 2.8 A |
Power line | 10m H07RN-F |
Wires | 4G1,0 |
Type of enclosure | IP 68 |
Winding thermostat | Yes |
Motor protection | In motor |
Plug | CEE-16A |
S3 | 10 % |

Performance | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Delivery head H [m] | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 | 16 |
Flow rate Q [m³/h] | 18.5 | 18 | 17.5 | 17 | 16.5 | 15.5 | 15 | 14 | 13 | 12 | 11 | 10 | 9 | 7.5 | 6 | 4.5 |
Specifications can be changed without notice. Performance subject to ISO 9906 tolerances.
The minimum flow velocity in the pressure piping must be 0.7 m/s according to EN 12056.
This data is represented in the performance curve as a limit of application.
Dimensions 08/2 M (mm)

Dimensions 08/2 M, EX (mm)

Example of pump base installation

Example of pump base installation with ex-proof

Example of guide rail installation

Example of guide rail installation with ex-proof

Example of guide rail installation

Example of guide rail installation with ex-proof

Single unit - min. sump (cm)
without GR: 40x40
with GR and swing-type check valve: 40x65
with GR and ball-type check valve: 40x65
Duplex unit - min. sump (cm)
without GR and swing-type check valve, check valve: 60x60
without GR and elbow-ball check valve: 60x80
with GR and duplex swing-type check valve: 60x60
with GR and duplex swing-type check valve or -valve: 65x85
Mechanical accessory | ||||||
---|---|---|---|---|---|---|
Code No. | ||||||
Chain | ||||||
certified, 2.5 m, 320 kg, 5 rings (EN 818 mod.) | JP45901 | |||||
certified, 5.0 m, 320 kg, 8 rings (EN 818 mod.) | JP45902 | |||||
certified, 7.5 m, 320 kg, 11 rings (EN 818 mod.) | JP47365 | |||||
Shackle, certified, 630 kg, stainless steel | JP45904 | |||||
Webbing | ||||||
with shackle | JP45168 | |||||
Guide rail system | ||||||
GR 35 | 1 1/2" female thread for MultiCut 08 without Ex-proof | JP29953 | ||||
Swing-type check valve | ||||||
R40 EN 12050-4 | 1½“ (DN 40), PN 4 | 150x120 (HxB) | JP00317 | |||
R50 EN 12050-4 | 2“ (DN 50), PN 4 | 150x120 (HxB) | JP00326 | |||
Ball-type check valve | ||||||
KE40 EN 12050-4 | 1½“ (DN 40), PN 6 | 170x125 (HxB) | JP47974 | |||
K50 EN 12050-4 | 2“ (DN 50), PN 6 | 185x155 (HxB) | JP44782 | |||
Stop valve | ||||||
brass, 1½“ (DN 40), PN 16 | 125x60 (HxB) | JP44786 | ||||
stainless steel, 1½“ (DN 40), PN 16 | 125x80 (HxB) | JP48403 | ||||
brass, 2“ (DN 50), PN 16 | 140x70 (HxB) | JP44787 | ||||
Elastic connection | ||||||
+ Hose band clamps, 1½“ (DN 40), PN 4 | 120x50 (HxD) | JP50902 | ||||
+ Hose band clamps, 2“ (DN 50), PN 4 | 150x63 (HxD) | JP50903 | ||||
Retaining plate | ||||||
for air bells (in concrete sumps from Ø 1 m) | JP50213 | |||||
Pipe connection | ||||||
1 1/4" (female thread) | JP16870 |
Electrical accessory | ||||||
---|---|---|---|---|---|---|
Code No. | ||||||
Alarm unit | ||||||
AG3 | subm. ball contact switch, mains dependent, potential-free contact,3 m cable | JP44891 | ||||
AG10 | subm. ball contact switch, mains dependent, potential-free contact, 9.5 m cable | JP44892 | ||||
Rechargeable battery | ||||||
9 V, for mains independent alarm | JP44850 | |||||
Seal leak detector | ||||||
DKG (für die Ölkammer) | JP44900 |