US 103 E Ex
JP09294Mechanical data | |
---|---|
Pump | Vertical single-stage |
Ex-proof | With ex-proof |
Free passage | 30 mm |
Bearing | Ball bearings, grease-lubricated |
Seal on motor side | Duplex rotary shaft seals |
Oil chamber | Yes |
Seal on medium side | SiC mechanical seal |
Run dry protection | Yes |
Shaft | Stainless steel |
Impeller | Vortex impeller, GFK |
Motor housing | Grey cast iron |
Submersible | Yes |
Pressure outlet | IG 1 1/2" |
Weight | 21.5 kg |
Electrical data | |
---|---|
Voltage | 1/N/PE~230 V |
Motor rating P1 | 1.37 kW |
Motor rating P2 | 0.98 kW |
Current | 6 A |
Power line | 10m H07RN-F |
Wires | 6G1,5 |
Type of enclosure | IP 68 |
Insulation class | F |
Winding thermostat | Yes |
Plug | Without |

Performance | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Delivery head H [m] | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 12 |
Flow rate Q [m³/h] | 28 | 26 | 23 | 21 | 19 | 17 | 15 | 12 | 10 | 8 | 2 |
Specifications can be changed without notice. Performance subject to ISO 9906 tolerances.
The minimum flow velocity in the pressure piping must be 0.7 m/s according to EN 12056.
This data is represented in the performance curve as a limit of application.




Single unit 1½" with GR 40: sump area min. 40x60 cm
Single unit 1½" without GR: sump area min. 40x40 cm
Duplex unit 1½" with GR 40: sump area min. 60x60 cm
Duplex unit 1½" without GR: sump area min. 40x60 cm
In case of installation beneath the backpressure level the pressure tube must be taken in a loop over the local backup level acc. to EN 12056. Besides, it must be secured with an EN 12050-4-proofed swing-type check valve. Additionally we recommend an alarm system.
In accordance with EN 12056-4 section 5.1, it has a built-in automatic spare pump or a double attachment included, which ensures that sewage drainage is not interrupted.
Suspend control unit in a dry room
Mechanical accessory | ||||||
---|---|---|---|---|---|---|
Code No. | ||||||
Swing-type check valve | ||||||
R40 EN 12050-4 | 1½“ (DN 40), PN 4 | 150x120 (HxB) | JP00317 | |||
DR 40 EN 12050-4 | 1½“ (DN 40), PN 4 | 200x280 (HxB) | JP09155 | |||
Ball-type check valve | ||||||
KE40 EN 12050-4 | 1½“ (DN 40), PN 6 | 170x125 (HxB) | JP47974 | |||
Stop valve | ||||||
brass, 1½“ (DN 40), PN 16 | 125x60 (HxB) | JP44786 | ||||
Elastic connection | ||||||
+ Hose band clamps, 1½“ (DN 40), PN 4 | 120x50 (HxD) | JP50902 | ||||
Elbow | ||||||
1½“ | JP45953 | |||||
Chain | ||||||
certified, 2.5 m, 320 kg, 5 rings (EN 818 mod.) | JP45901 | |||||
certified, 5.0 m, 320 kg, 8 rings (EN 818 mod.) | JP45902 | |||||
Webbing | ||||||
with shackle | JP45168 | |||||
Guide rail system | ||||||
GR 40 | JP25592 |
Electrical accessory | ||||||
---|---|---|---|---|---|---|
Code No. | ||||||
Level control | ||||||
Auxiliary switch unit ExH-A | for ex-proof pumps only (single-units) | JP16720 | ||||
Control for single units | ||||||
Control unit AD 8 XE | for US 103E E | JP25902 | ||||
Level control | ||||||
Subm. switch pack AmG | 2 subm. ball contact switch with 9.5 m and counterweight | JP16719 | ||||
Level control | ||||||
Dry run protection US_Ex | JP44603 |