Flutbox
JP09479Mechanical data | |
---|---|
Pump | Vertical single-stage |
Free passage | 20 mm |
Bearing | Ball bearings, grease-lubricated |
Seal on motor side | Rotary shaft seal |
Oil chamber | Yes |
Seal on medium side | 2-fold rotary shaft seals |
Run dry protection | Yes |
Shaft | Stainless steel |
Impeller | Vortex impeller, GFK |
Motor housing | Stainless steel |
Pump housing | GRP |
Submersible | Yes |
Pressure outlet | C-coupling |
Weight | 11 kg |
Electrical data | |
---|---|
Ciruit | With built-in level control |
Voltage | 1/N/PE~230 V |
Motor rating P1 | 0.52 kW |
Motor rating P2 | 0.38 kW |
Current | 2.3 A |
Power line | 10m H07RN-F |
Wires | 3G1,0 |
Type of enclosure | IP 68 |
Insulation class | B |
Winding thermostat | Yes |
Motor protection | Integrated |
Plug | Safety |
Performance | |||||||
---|---|---|---|---|---|---|---|
Delivery head H [m] | 1 | 2 | 3 | 4 | 5 | 6 | 7 |
Flow rate Q [m³/h] | 11,5 | 10,5 | 9 | 7,5 | 6,5 | 4,5 | 2,5 |
Specifications can be changed without notice. Performance subject to ISO 9906 tolerances.
The minimum flow velocity in the pressure piping must be 0.7 m/s according to EN 12056.
This data is represented in the performance curve as a limit of application.
Dimensions Flutbox mm